For soffit size see details.
Structural floor framing plan example.
Figure 10 20 is an example of a roof framing plan for a wood frame roof.
Draft structural floor and roof framing plans terminologies and examples slideshare uses cookies to improve functionality and performance and to provide you with relevant advertising.
The structural integrity and successful performance of the roof structure during high wind events depends upon.
With this in mind we developed the plans drawings checklist as a way to determine the types of drawings and level of detail based on the client s needs and experience.
For spans and dimensions refer to floor.
It is a framing road map of how the house should fit together.
Ensuring that the frame s built the way it s intended is very important from an engineering perspective and it s likely that separate framing plans.
A structural drawing or a structural plan is composed of structural details and a general arrangement plan or layout necessary for site construction proper.
Rafters are shown in the same manner as joists.
Fascia to be 2 x douglas fir.
Steel timber sizes spacings and numbers of the structural elements that will be used to build your house.
Install all trusses as per truss manufacturer installation guidelines.
Roof framing and 3 adequate connections between the roof structure and the top of the wall to create a complete vertical load path.
The framing plan along with the structural sections is the sheet most referred to by the carpenter in the field.
3 place vaults where possible as indicated on the floor plan 4.
The framing plan shows the size spacing and direction of all roof rafters and ceiling joists.
It is primarily intended for a structural engineer for example.
Multiple types of individual design views are noted below as part of different plan sheets any of which may be used on a particular project and their inclusion and level.
A framing plan is a plan that s designed to show the locations materials e g.
8 12 and 6 12 pitch roof framing scale 1 16 1 main floor framing scale 1 16 1 5 roof framing.
Wind loads above figure 1609 basic wind speed 3 second gust 33 feet above ground exposure c ibc 2003 zone v 30 mph 1 2 3 70 80 90 western mass central mass.
1 adequately designed and spaced roof framing members 2 adequate lateral bracing to support.
In these drawings all the details that we need to follow during site construction is being reflected.
The roof framing plan is drawn in the same manner as the floor framing plan.