Draw the actual room sensible heat factor line through the room design conditions parallel to the base line in step 1 3 4 fig.

The actual room sensible heat factor line is.

Q sr sensible heat load in room kw btu hr. The rshrs have all been averaged together for. If for example a room had a total. The room sensible heat factor line can also be drawn on the psychrometric chart without knowing the condition of supply air.

75 db 50 rh. Room sensible heat ratio rshr is the ratio of sensible heat to total heat including latent for a room or zone. Effective room latent heat erlh is the sum of all latent heat gain that occurs in the room including the gain due to the portion of the ventilation air which is bypassed. In this scenario a room to room load calculation has been done on a home.

It can be expressed as. Assuming a room to room load calculation has been done on a building the next step in utilizing the psychrometric chart would be to plot out the room sensible heat ratio lines for each zone. As shown this line may be drawn to the saturation line on the psychrometric chart. Effective room sensible heat ersh is the sum of all sensible heat gain that occurs in the room including the gain due to the portion of the ventilation air which is bypassed.

The following procedure illustrates how to plot this line using the calculated rshf the room design conditions the sensible heat factor scale in the upper right hand corner of the psychrometric chart and the alignment circle at 24 c dry bulb and 50 relative humidity. Rshf q sr q tr 1. 95 db 75 wb. The room sensible heat factor rshf expresses the ratio between sensible heat load and total heat load in a room.

Module 14 The Psychrometrics Of Air Conditioning Systems Cibse Journal

Module 14 The Psychrometrics Of Air Conditioning Systems Cibse Journal

Https Hvac Eng Com Psychrometric Processes

Https Hvac Eng Com Psychrometric Processes

Module 11 The Psychrometrics Of Hvac Sub Systems Cibse Journal

Module 11 The Psychrometrics Of Hvac Sub Systems Cibse Journal

Effective Room Sensible Heat Ersh Is The Sum Of All Sensible Heat Gain That Course Hero

Effective Room Sensible Heat Ersh Is The Sum Of All Sensible Heat Gain That Course Hero

Source : pinterest.com